Panasonic KX-TC2000NZW Telephone User Manual


 
11.2. How to change the channel
*: Refer to Flow Solder Side View (P.68).
11.3. Adjustment
Adjustment Items Test Mode Adjustment
Point
*Procedure Check or
Replace
Parts
(A) RX VCO
Confirmation
3ch Talk -
Confirm so that the reading of the Digital Voltmeter is 2.0V ± 1.0V.
IC1, L10,
C26, R14
(B) TX VCO
Adjustment
3ch Talk T6
Adjust T6 so that the reading of the Digital Voltmeter is 2.0V ± 0.3V.
IC1, DV1,
T6
(C) TX Frequency
Adjustment
3ch Talk VC1
Adjustment VC1 so that the reading of the frequency counter is
30.1750MHz ± 100Hz.
IC, X1, T6,
DV1, C35,
C40, VC1
(D) TX Power
Adjustment
3ch Talk T5
Adjust T5 so that the reading of the RF VTVM is more than 9dBm.
IC1, Q3,
Q4, Q5,
T5, DPX1
(E) RX Sensitivity
Confirmation
(2nd IF output)
3ch Talk T2 1. Apply 60dBuVemf output from S.S.G. (modulation frequency 1KHz, dev.
0KHz).
2. Confirm that the reading of RF VTVM is the maximum value (more than
20mV)
DPX1, T2,
CF1, CF2
(F) Line Output Level
Confirmation
3ch Talk - 1. Apply 60dBuVemf output from S.S.G. (modulation frequency 1KHz, dev.
3KHz).
2. Confirm that the reading of AF VTVM is more than 120mV (600 load).
IC1, Q11
(G) Line Input
Modulation
Confirmation
3ch Talk - 1. Input via loop simulator 1.0KHz, -20dBm (measured at T-R) signal.
2. Apply 60dBuVemf output from S.S.G. (modulation frequency 1KHz, dev.
0KHz).
3. Confirm so that the reading of FM Deviation Meter is 2.8KHz ± 0.3KHz.
IC1, DV1
(H) Noise Squelch
Confirmation
3ch Talk - 1. Measure the SSG output level when the noise squelch changes from Low
to High.
2. Confirm that the SSG output level is -10 ~ +5dBuVemf.
IC1, DPX1
* : The connection of adjustment equipment are as shown in Adjustment Standard (Base Unit) (P.27).
SSG Frequency: 39.875 MHz
26
KX-TC2000NZB / KX-TC2000NZW / KX-TC2000NZF