Bosch Appliances 00 and LBB 4141 Wireless Office Headset User Manual


 
DCN Voting Units Installation and User Instructions
en | 7
Bosch Security Systems B.V. | June 2004 | 9922 141 70611
mounting. In stage 3: fasten the screws of the coupling
pieces, in order to fixate the coupling pieces.
Figure 2.10 Block mounting a voting unit in a table
Figure 2.11 Dimensions for block mounting
2.4.3 De-mounting
Follow the mounting procedure in reverse. Use a
spatula to remove the end caps and a screwdriver to
unlock the click-to-fit mechanism of the voting unit.
i Note
Take care not to damage the furniture while
removing the end caps and voting unit. Replace
the end caps in case those are damaged.
2.5 Connecting
The LBB 4141/00 and LBB 4140/50 voting units can
be directly connected to the trunk line in a loop-
through chain (see
Figure 2.12).
See the DCN Installation and Operating Manual for
the system limits and for how to design and install a
DCN system.
Figure 2.12 Direct loop-through connection
i Note
An unused output cable must be terminated by
an LBB 4118/00 Termination Plug.
2.6 Initializing
When all the units in a system have been installed,
the system must be initialized and made ready for use
once. The initialization procedure enables all DCN
units installed to be recognized by the CCU.
Recognition is given in the form of an address,
allocated by the CCU to each active unit in the
system.
See chapter 11 of the DCN Installation and
Operating Manual for how to initialize and assign
seat numbers in a PC-based system.
>