Aiphone RY-18L Intercom System User Manual


 
NOTE:
Release contacts on the JF-2MED are from
4-pin connector included with unit. Connect
Red & Brown wires as shown. Orange &
Yellow wires are not used.
Release contacts on the JF-1MD are L/L
terminals.
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
TOLL FREE TECHNICAL SUPPORT: (800) 692-0200
TOLL FREE FAX LINE: (800) 832-3765
E-MAIL: tech-serv@aiphone.com
RY-18L Instr.
0307JD
SPECIFICATIONS:
Power Source: Supplied by master station
Mounting: No mounting required
Terminations: Color-coded prewired pigtails
Relay Input: 12-18V DC, Red, Gray wires, 22AWG
Relay Output: Brown, Red, Orange wires, 18AWG
N/O Output rating: 5A at 30V DC
10A at 125V AC
3A at 250V AC
N/C Ouptut rating: 3A at 30V DC or 125V AC
Wiring: 2 conductors from monitor's door release contacts to RY-18L.
2 conductors from RY-18L to strike, with power for strike wired in series.
Dimensions (HxWxD): 1-3/4" x 7/8" x 7/16", with wires extending approx. 7-1/2"
WIRING DIAGRAMS:
A1
A2
B1
B2
S
S
DC 18V
+
-
RELEASE
(L)BRN
(L)RED
JF-1MD/
JF-2MED
JF-DA
JF-DV
JF-DVF
A1
A2
PS-1820UL
+
-
.
Red
Gry
Brn
Org
Yel
COM
N/O
N/C
Use Normally Open
contact for electric strike
ELECTRIC STRIKE
WIRING METHOD:
JF OPEN VOICE COLOR VIDEO SYSTEM:
PS-1820UL
+
-
.
Red
Gry
Brn
Org
Yel
COM
N/O
N/C
Use Normally Closed
contact for magnetic lock
MAGNETIC LOCK
WIRING METHOD:
A1
A2
B1
B2
S
S
DC 18V
+
-
RELEASE
(L)BRN
(L)RED
Add
jumper
wire from
BRN to +
Add
jumper
wire from
BRN to +
NOTE:
Only wiring pertaining to connection of door
release relay is shown here.
For complete system information, please
consult the main system installation manual.
JF-1MD/
JF-2MED
+ -
LOCK
POWER
+ -
LOCK