13.2. Accessing USB FIFO Space
The C8051F340/1/2/3/4/5/6/7 include 1k of RAM which functions as USB FIFO space. Figure 13.1 shows
an expanded view of the FIFO space and user XRAM. FIFO space is normally accessed via USB FIFO
registers; see
Section “16.5. FIFO Management” on page 171 for more information on accessing these
FIFOs. The MOVX instruction should not be used to load or modify USB data in the FIFO space.
Unused areas of the USB FIFO space may be used as general purpose XRAM if necessary. The FIFO
block operates on the USB clock domain; thus the USB clock must be active when accessing FIFO space.
Note that the number of SYSCLK cycles required by the MOVX instruction is increased when accessing
USB FIFO space.
To access the FIFO RAM directly using MOVX instructions, The USBFAE bit in register EMI0CF must be
set to ‘1’. When this bit is set, the USB FIFO space is mapped into XRAM space at addresses 0x0400 to
0x07FF. The normal XRAM (on-chip or external) at the same addresses cannot be accessed when the
USBFAE bit is set to ‘1’.
Important Note: The USB clock must be active when accessing FIFO space.
Figure 13.1. USB FIFO Space and XRAM Memory Map with USBFAE set to ‘1’