3.4.7 MAC Address
IEEE specification requires the manufacturer to store a unique 6-byte MAC or Ethernet Address
in the permanent memory of each network device. The MAC address of the LIP-6812/LIP-6830
can be viewed but not changed.
To view the MAC address:
1) Press the button.
2) Press button, or move cursor to 1.Network Configuration using the [Next]/[Prev]
Softkeys, and press the [ OK ] Softkey.
3) Press button, or move cursor to 7.MAC Address using the [Next]/[Prev] Softkeys, and
press the [ OK ] Softkey.
4) View the MAC (Ethernet) Address of your LIP-6812/LIP-6830.
5) Press the button to exit from the menu.
3.4.8 VLAN Settings
VLAN settings define the Ethernet frame priority and VLAN identification in accordance with
IEEE 802.1p/Q standards. Separate VLAN tags are assigned for the LIP-6812/LIP-6830 PC
port and the LAN (voice) port. When the VLAN id is assigned, only frames with the assigned ID
are accepted and all voice frames sent by the LIP-6812/LIP-6830 include the VLAN ID assigned
to the LAN port.
For proper operation, other network elements (LAN switches and Default Gateway)
must support and be configured with proper the VLAN parameters.
VLAN settngs can not be changed if CDP is enabled.
Changing VLAN parameters requires a reboot of the LIP-6812/LIP-6830; when you
leave the menu, you will receive a Reboot notice.
3.4.8.1 VLAN Priority (LAN)
The VLAN Priority (LAN) establishes the priority for Ethernet frames from the LIP-6812/LIP-
6830 voice port including signaling and voice packets. Setting the VLAN ID to 0 disables VLAN
framing and only standard Ethernet frames are sent.
To assign VLAN prioity for the LAN (voice) port:
1) Press the button. If the LCD Menu is locked, use the unlock procedure (refer to
Section 3.3 Lock/Unlock Configuration).
2) Press button, or move cursor to 1.Network Configuration using the [Next]/[Prev]
Softkeys, and press the [ OK ] Softkey.
MAC Address
00:40:5A:00:00:00