Nortel Networks LIP-6812 Telephone User Manual


 
LIP-6812 & LIP-6830 Installer Guide
Rev. 01.04 D-11 June 07
dhcp_get_http
(Optional) Whether to get a HTTP URL using option 160 on
DHCP. Valid values are disable and enable.
Default is enable.
https_url
(Optional) Specifies an URL string for HTTPS provisioning
server.
Max 255 characters are available.
https_opt
(Optional) Specifies a DHCP option number for HTTP/HTTPS
URL.
Valid values are 1 to 255.
Default is 160.
https_port
(Optional) Specifies the port of HTTPS web server.
Valid values are 0 to 65535.
Default is 443.
https_id
(Optional) Specifies the ID to authenticate for HTTPS session.
Max 50 characters are available.
https_password
(Optional) Specifies the password to authenticate for HTTPS
session.
Max 50 characters are available.
https_macform
(Optional) Specifies the filename of phone specific
configuration file. “$MAC” will be replaced by the MAC
address. “$MAC must be included in the files name or path
Max 50 characters are available.
Default is “$MAC”.
verifying_cert
(Optional) Specifies the hexadecimal value composed by a 3-
bit field flag for HTTPS certification verification. 0x01 checks
valid certification authority. 0x02 checks whether a server
name is valid. 0x04 checks whether a certification is expired.
Valid values are 0 to 7.
Default is ff.
decrypt_key
(Optional) 32 byte hexadecimal 3DES decryption key.
smartup_use
(Optional) Enables or disables using Smart Update. Valid
values are disable and enable.
Default is enable.
smartup_type
(Optional) Specifies the type of Smart Update.
Valid values are as follows:
1 — checks new version periodically
2 — checks at the specific time per day
Default is 2.
smartup_interval
(Optional) Specifies the interval of periodical checking. Valid
values are 0 to 86400 seconds.
Default is 3600.
smartup_time
(Optional) Specifies the time of the day to check new version.
Valid values are 0 to 23 o’clock.
Default is 00:00.
PROVISI
ON
smartup_confirm
(Optional) Enables or disables to confirm that the phone is
rebooted when new version is found.
Valid values are disable and enable.
Default is enable.
Table D-1 Configuration Parameters