Nortel Networks LIP-6812 Telephone User Manual


 
LIP-6812 & LIP-6830 Installer Guide
Rev. 01.04 D-3 June 07
sntp_server_address
(Optional) IP address or URL of the SNTP server from which
the phone obtains time data.
interval
(Optional) Duration (interval), in hours, between time sync
with sntp server.
Valid values are 0 to 120.
Default is 1.
timezone
(Optional) Time zone in which the phone is located.
Valid values are region numbers representing various time
zones shown in Table 2.
Default is 3 (Pacific Standard).
time_format
(Optional) Time format for LCD displaying.
Valid values are 0 (off), 1 (12H) or 2 (24H).
Default is 2.
date_format
(Optional) Date format for LCD displaying.
Valid values are 0(off) 1(MM/DD) 2(DD/MM) 3(DD Mon)
4(Mon DD).
Default is 3.
dst_auto_adjust
(Optional) Whether daylight savings time (DST) is
automatically adjusted on the phones.
Valid values are 0 (do not adjust) or 1 (adjust).
Default is 1.
dst_start_month
(Optional) Month in which DST starts.
Valid values are 1 to 12, with 1 being January and 12 being
December. In the United States, the default is 3.
dst_start_day
(Optional) Day of the month on which DST begins.
Valid values are the following:
1 to 31 (for days of the month)
0 (ignore this field and use the value in the
dst_start_day_of_week parameter instead)
Default is 0.
dst_start_day_of_week
(Optional) Day of the week on which DST begins.
Valid values are 1 to 7 (1 is Sunday; 7 is Saturday). In the
United States, the default is 1.
dst_start_week_of_month
(Optional) Week of month in which DST begins.
Valid values are 1 to 6 and 7 (1 is the first week; each
subsequent number is a subsequent week; 7 is the last
week in the month regardless of which week the last week
is). In the United States, the default is 2.
dst_start_time
(Optional) Hour of day on which DST begins.
Valid values are 0 to 23. In the United States, the default
is 2.
dst_stop_month
(Optional) Month in which DST ends.
Valid values are 1 to 12 with 1 being January and 12 being
December. In the United States, the default is 11.
dst_stop_day
(Optional) Day of the month on which DST ends.
Valid values are as follows:
1 to 31 (for the days of the month)
0 (ignore this field and use the value in the
dst_stop_day_of_week parameter instead)
Default is 0.
dst_stop_day_of_week
(Optional) Day of the week on which DST ends.
Valid values are 1 to 7, with 1 being Sunday and 7 being
Saturday. In the United States, the default is 1.
NETTIME
dst_stop_week_of_month (Optional) Week of month on which DST ends.