Chapter 3 ROM Monitor Commands
3-22
mop
This release does not support this command.
The mop command sets the MOP load/dump address. This is useful
when the loading the Remote Annex 6300’s operational image from
a VAX VMS load host. The command syntax is:
mop [–d]
The mop command display looks like this:
The mop –d command displays the current MOP settings:
monitor:: mop
Enter preferred MOP load/dump address [<uninitialized>]::
Load Broadcast Y/N [Y]::
monitor:: mop –d
MOP preferred load/dump address: <uninitialized>