#RINGCOUNTSet Number of Rings/Automatic Operation
Description: This parameter defines the number of rings that will be counted before an automatic operation
occurs when receiving an incoming call.
It applies only when the ANSWERMODE parameter is set to an automatic mode (value>0).
If the ANSWERMODE parameter is used, the RINGCOUNT value must also be >0.
Syntax: AT#RINGCOUNT=<value>
AT#RINGCOUNT? Read or display the current setting (or AT#VPHY, AT#VALL).
Values: Integer between 0 and 15 inclusive.
0 = modem will not answer.
1-15 = modem will answer on the ring number selected.
Default: 0
#DIALN1Set Primary Dial-Up Number
Description: This parameter is the primary dial-up phone number that will connect with the local ISP. Length
depends on country/region.
Syntax: AT#DIALN1="<value>"
AT#DIALN1? Read or display the current setting (or AT#VPHY, AT#VALL).
Values: Decimal phone numbers.
Default: None
#DIALN2Set Secondary Dial-Up Number
Description: This parameter is the secondary dial-up phone number that will connect with the local ISP.
Length depends on country.
Syntax: AT#DIALN2="<value>"
AT#DIALN2? Read or display the current setting (or AT#VPHY, AT#VALL).
Values: Decimal phone numbers.
Default: None