ClearOne comm 600 Conference Phone User Manual


 
RAV-Ware — Configuring System Settings
RAV-Ware — Configuring System Settings
Regional Settings
In the Regional Settings window, you can configure the date and time to ensure an accurate
time stamp on log files.
To open Regional Settings
Click the
Regional Settings
icon in the Configuration screen.
To set date and time
1. Select
Use Local Time
if you want to use
the time on your local computer.
– Or –
Clear the
Use Local Time
checkbox and
enter the
IP address
for the time server.
2. Select
Use Daylight Savings
if your region
observes daylight savings time.
3. Select your
Time Zone
and click
OK.
4. Click Ye s to confirm changes.
Telephone Settings
In the Telephone Settings window you can set telephone preferences such as auto-answer,
auto-disconnect, ringer melody and program the local number.You can also adjust the telco
level control, country setting and the flash settings.
To open Telephone Settings
Click the
Telephone Settings
icon in the Configuration screen.
Figure 3.13. Date/Time settings
33
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
To change the User Name and Password
1. In the Networking tab, click
User/Password
.
2. Specify the
User name
. (Default is clearone.)
3. Type the
Password
. (Default is rav.)
4. Retype the password to confirm.
5. Click
OK
to save changes and close the window.
Note
: This option is only available when you are
connected to a RAV unit.
To configure the Camera port
1. In the Serial tab, set the
Baud Rate
to match the
baud rate indicated in the camera specifications.
2. Select
Flow Control
to enable hardware flow
control.
3. Click
OK
to save settings and close the window.
To configure the Control port
1. Set the Control Port
Baud Rate
to match the baud
rate of the PC COM port or the control device.
2. Select
Flow Control
to enable hardware flow
control. (Flow Control is selected as default.)
3. Click
OK
to save settings and close the window.
Note: Flow Control is the regulation of information between two devices that are connected to
one another. ClearOne recommends enabling Flow Control on the RAV system.
Attention
:If you are connected to the RAV unit through the serial port,you will need to reboot
the unit before the baud rate and flow control changes take place. If you are connected to the
RAV unit through the USB port, changes are made instantly.
To change RF frequency channel
1. In the Frequency tab, select a frequency.
2. Click
OK
to save settings and close the window
Note
: The channel frequency allows the mixer to
communicate with the controller.The frequency used
by RAV-Ware must match the frequency used by the
controller. See page 58 to set the controller
frequency.
Attention
: If you are using the European or South
African version of RAV Frequency 1 and Frequency
8 are the same frequency.
Figure 3.11. Serial settings
32
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Figure 3.10. User name/Password
Figure 3.12. Frequency settings
!
!