WIRING DIAGRAM: Dual Master LEM-1DL System with DAK-2S Dual Master Adaptor
OPERATION NOTES:
1. Only one master can be used at a time.
2. If both masters are activated, a feedback (squeal) will be heard through the system when either TALK button is pressed.
3. If feedback occurs, press the OFF button on one of the LEM-1DL masters.
INSTALLATION GUIDELINES:
1. Use 2 conductor shielded wire from the door station to the first master, then to the second master.
2. Install the units at the desired locations.
3. Separate PT-1210N power supplies are required for each master station.
4. Install the bare wire leg of the component module directly onto the "1" terminal of the LEM-1DL's.
5. Attach the wire coming form the "1" terminal of the LE-D to the colored wire end of the component modules at both masters. (The component modules
will easily fit within the space available.)
6. Connect the "E" terminals between the door station and master stations.
7. If door release is included, use a separate 2-conductor wire from the "EL" terminals of the masters through an AC transformer and to the door strike.
8. The EL-9S is designed for a standard wood framed door, and for light and medium usage. If a different type of door is used, install a strike appropriate
for the door.
9. The door release button on the master station is a "Normally Open" contact closure.
Component
Module*
Component
Module*
PT-1210N
PT-1210N
LE-D
1
E
-
Door Strike
Please read and understand all
instructions before installation.
IMPORTANT!!!
Each master REQUIRES
an individual power supply.
1
E
+
-
EL
EL
LEM-1DL
4 LEM-1DL Master Stations with 1 Door
LE-D
1
E
-
1
E
+
-
EL
EL
LEM-1DL
Component
Module*
Door Strike
Component
Module*
1
E
+
-
EL
EL
LEM-1DL
1
E
+
-
EL
EL
LEM-1DL
Component
Module*
1
E
+
-
EL
EL
LEM-1DL
Component
Module*
Leave E/-
jumper
attached
Power Source
for door strike
o
o
Electric strike shown is being powered from
same transformer powering the first LEM-1DL.
LEM-1DL Supplement
Pg. 2
NOTE: In a multi-master system, all masters only talk to the
door station, and only one master can be on at a time.
1
E
+
-
EL
EL
LEM-1DL