Aiphone FK1628 B P0811JZ Intercom System User Manual


 
11
Connections (IS-IPDV and IS-IPDVF)
NO
COM
NC
DC
24V
P
PT
LAN/PoE
CAT5e/6
*1: A power supply unit is not needed when using a switch or injector that has a PoE (Power over Ethernet) function. The unit is supplied with power
along with data signal via a LAN cable.
*2: Output speci cations
Output method N/O or N/C dry closure contact
Voltage between
terminals
24V AC, 0.5A (resistive load)
24V DC, 0.5A (resistive load)
Minimum overload (AC/DC):
100mV, 0.1mA
NOTES:
Do not use the unoccupied terminals and ports for other purposes.
In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.
For connecting other manufacturer’s products, refer to the instruction manuals for those products.
The illustration of the unit’s rear panel differs from the actual one. This is for simplifying the connection diagram.
AC transformer
The terminals are inside the terminal
cover. After connecting, route the
wires through the wiring paths, then
close the cover.
Be sure to route the CAT5e/6 cable
and option wires through inlet.
When closing the terminal cover,
close it until it clicks.
Electric door strike
*2
(non-shielded)
Terminal cover
Inlet
CAT5e/6 cable
Option
wires
Connect to the electric door strike
according to its speci cations.
Switch (Hub)
P: Polarized
15m (50')
100m (330')
10m (33')
10m (33')
10m (33')
φ
0.65-1.2 (22-16AWG)-2C
φ
0.65-1.2mm
(22-16AWG)
φ
0.65-1.2mm
(22-16AWG)
φ
0.65-1.2mm
(22-16AWG)
Power supply unit *1
(PS-2420/D/UL/S)
10BASE-T/100BASE-TX