Aiphone C-123LW Intercom System User Manual


 
90102 0610
C-123LW Supplement
Pg. 1
The C-123LW Dual Master ChimeCom set provides chime, communication, and door release for one door and two
inside locations. This supplemental instruction manual addresses many of the additional functions and modi cations
for the Chime Com system, including installation and troubleshooting information.
C-123LW Supplemental Instructions
Dual Master ChimeCom System
- REFER TO INSTALLATION MANUAL INSIDE C-123L/A BOX FOR STANDARD
INSTALLATION INFORMATION -
MASTER STATION:
C-ML/A: Master station with door release button (Normally Open)
COMPATIBLE DOOR STATIONS:
(Weather resistant, made for outdoor use)
C-D Surface mount, included in C-123L/A and C-123LW kit
LE-D Surface mount, plastic door station (replacement for C-D)
LE-DA Flush mount in 2-gang box, stainless steel cover
LE-SS-1G Vandal resistant, 1-gang ush mount, stainless steel
LE-SS Vandal resistant, 2-gang ush mount, stainless steel
LE-SSR Vandal resistant, 2-gang ush mount, stainless steel, red mushroom button
LS-NVP/C Vandal resistant, 3-gang ush mount, white powder-coat nish
OPTIONAL COMPONENTS & ACCESSORIES:
RY-AC/A External signaling relay (Requires 12VDC power supply)
DAK-2S Dual master adaptor kit (2component modules)
(1 kit per 2 master stations. Use 2 DAK-2S for up to 4 total master stations)
SBX-1G Surface mount box for LE-SS-1G
SBX-2G Surface mount box for LE-SS, LE-SSR, LE-DA
SBX-NVP Surface mount box for LS-NVP/C
EL-12S Door strike (for interior wood frame doors only)
PT-1210N AC 12V Transformer (used for door strike)
SKK-620B 6V DC power supply (1 per C-ML/A master)
822202 2 conductor, 22AWG, Shielded wire for up to 245’, (500’ and 1000’ boxes)
821802 2 conductor, 18AWG, Shielded wire for up to 590’, (1000’ box)
Install two separate runs of this cable, one for the intercom and one for
the door release.
DOOR RELEASE WIRES MUST BE IN A SEPARATELY JACKETED CABLE FROM THE INTERCOM WIRING.
C-123LW Set contains:
2 C-ML/A, 1 C-D, 1 DAK-2S
Power source and Door Strike not included.
2 cond. shielded for intercom
C-123L/A Set
LE-SS-1G LE-DA
LS-NVP/C
LE-SS
DAK-2S
(2 component modules per kit)
Separate 2 conductor for door release
C-D
C-ML/A
SKK-620B
Power
Source
for Strike
(or 4 “C” batteries installed in
the master). Do not use both
power sources. Ground wire
must be tied to earth ground
when using the SKK-620B.
IMPORTANT: Connect wires
before applying power.
EL-12S, not included with the C-123L/A or C-123LW set.