3D Connexion CA-100Plus Two-Way Radio User Manual


 
CRT COLOR ANALYZER
Dimensions
340
216
127
11017
70
1422 m / 5 m47.4
φ60
30.2
φ44
ISO 5
mm screw
(depth : 6
mm)
60
φ
45
(Units :mm)
Receptor
Display range Luminance
Chromaticity
*1 The chromaticity and luminance are measured under Konica Minolta’s condition (standard CRT (6500 K) is used).
*2 The luminance for monochrome is measured when the reading of luminance for white is 40.00 cd/m
2
.
*3
Measuring probe connected to probe connector P1 only,used USB (used RS-232C
Baud rate: 38400 bps
)
*4 At the CA-200 mode
Select the probe among the four types.
Specifications are subject to change without notice.
Specifications
Detector : Silicon photo cell
0.05 to 1000 cd/m
2
±2 %±1 digit of reading (temperature : 23°C±2°C, relative humidity : (40±10)%)
0.05 to 1000 cd/m
2
xyLv, TuvLv, RGB, XYZ, u'v'Lv
x, y, Lv, R/G, B/G, G, R, B/R, G/R
NTSC, PAL, EXT, UNIV, INT
Vertical syncronizing frequency : 40 to 200 Hz
100 channels
Standard function
0 to 28°C : relative humidity 70 % or less with no condensation
28 to 40°C : relative humidity 40 % or less with no condensation
100-240 V
~
, 50-60 Hz 50 VA
340 × 127 × 216 mm (W × H × D), φ45 × 142 mm
3.58 kg, 285 g
0.01 to 1000 cd/m
2
Displayed in 4 or 3-digit value (Can be chosen)
0.05 to 1000 cd/m
2
0.2 %+1 digit (2 σ)
0.05 to 0.19 cd/m
2
±0.006 (for white)
0.20 to 0.49 cd/m
2
±0.004 (for white)
0.50 to 1000 cd/m
2
±0.003 (for white)
40.00 cd/m
2
±0.002 (for white), ±0.004 (for monochrome)*2
0.05 to 0.19 cd/m
2
0.006 (2 σ)
0.20 to 0.49 cd/m
2
0.002 (2 σ)
0.50 to 1000 cd/m
2
0.001 (2 σ)
0.05 to 0.99 cd/m
2
5 measurements/sec. (4.5 measurements / sec.)
*4
1.00
to 1000 cd/m
2
20 measurements/sec. (17 measurements / sec.)
*4
USB (1.1 conformity) , RS-232C (38,400 bps or below)
Max. 5 points (Use 4-Probe Expansion Board CA-B04)
Temperature : 10 to 28°C; relative humidity 70 % or less with no condensation
Luminance change : ±2 % ±1 digit of reading for white
Chromaticity change : ±0.002 for white, ±0.006 for monochrome
from reading of Konica Minolta's standard CRT*1, 40.00 cd/m
2
, with 23°C 40 %
0.05 to 2000 cd/m
2
0.05 to 2000 cd/m
2
0.01 to 2000 cd/m
2
0.05 to 2000 cd/m
2
0.2 %+1 digit (2 σ)
0.05 to 0.09 cd/m
2
±0.008 (for white)
0.10 to 0.39 cd/m
2
±0.006 (for white)
0.40 to 0.99 cd/m
2
±0.004 (for white)
1.00 to 2000 cd/m
2
±0.003 (for white)
40.00 cd/m
2
±0.002 (for white), ±0.004 (for monochrome)*2
0.05 to 0.09 cd/m
2
0.009 (2 σ)
0.10 to 0.39 cd/m
2
0.006 (2 σ)
0.40 to 0.99 cd/m
2
0.002 (2 σ)
1.00 to 2000 cd/m
2
0.001 (2 σ)
0.05 to 1.99 cd/m
2
5 measurements/sec. (4.5 measurements / sec.)
*4
2.00
to 2000 cd/m
2
20 measurements/sec. (17 measurements / sec.)
*4
Mac OS 10.3.7J Adobe Illustrator10J
2006.11.15
C M Y K
System Diagram
Measuring Probe (2 m) CA-P02
Measuring Probe (5 m) CA-P05
High luminance Measuring Probe (2 m) CA-PH02
High luminance Measuring Probe (5 m) CA-PH05
(Optional)
PC (Commercially available)
PC-AT compatible
CA-100Plus
AC Power Cord (Standard)
PC Software for Color Analyzer
CA-SDK(Standard)
4-Probe Expansion Board
CA-B04
(Optional)
Multi-Probe
Measuring Probe Holder
CA-A11(Standard)
CA-100Plus(Measuring Probe 2 m or 5 m)
CA-100Plus(High luminance Measuring Probe 2 m or 5 m)
Measuring Probe (2 m) CA-P02
Measuring Probe (5 m) CA-P05
High luminance Measuring Probe (2 m) CA-PH02
High luminance Measuring Probe (5 m) CA-PH05
Luminance Measurement range
Accuracy (for white)*1
Repeatability *1
Chromaticity Measurement range
Accuracy *1
Repeatability *1
Measurement speed xyLv
Display Digital
Analog
SYNC mode
Object under measurement
Memory channel
Analyzer function
Interface
Multi-point Measurement
Operating temperature/humidity range
Storage temperature/humidity range
Input voltage range
Size Mainbody, Probe
Weight Mainbody, Probe
Type 1:Helvetica,Helvetica-Bold,Helvetica-BoldOblique,Symbol,TimesNewRomanPS-ItalicMT,ZapfDingbats
CRT
(temperature : 23°C±2°C,
relativehumidity: (40±10)%)
*3
A
G
M
E
P
K
Printed in Japan9242-4885-12
©2003 KONICA MINOLTA SENSING, INC.
SAFETY PRECAUTIONS
9
For correct use and for your safety,be sure to read
the instruction manual before using the instrument.
Always connect the instrument to the
specified power supply voltage.
Improper connection may cause a fire
or electric shock.
Certificate No : JQA-E-80027
RegistrationDate: March12,1997
Certificate No :YKA 0937154
RegistrationDate: March3,1995