8. Technical Data
Type WFP 3000 WFP 5000
Art. No. 7909 7910
Rated power 7.5 W 9.5 W
Flow 16.5 l/min 30.5 l/min
Max. delivery head 1.6 m 2.0 m
Max. submersion depth 1.0 m 1.0 m
Power cable 10 m H05 RNF 10 m H05 RNF
Fitting 26,5 mm (G 3/4) male thread 26,5 mm (G 3/4) male thread
Max. media temperature 35°C 35°C
Mains voltage 230 V 230 V
Frequency 50 Hz 50 Hz
Noise level L
WA
1)
48 dB(A) 48 dB(A)
1) Measuring method according to EN 60335-1
Performance characteristics
EU Certificate of Conformity
The undersigned
GARDENA Kress + Kastner GmbH · Hans-Lorenser-Str. 40 · D-89079 Ulm
hereby certifies that, when leaving our factory, the units indicated below are in accordance with the
harmonised EU guidelines, EU standards of safety and product specific standards.
This certificate becomes void if the units are modified without our approval.
m
2,5
2,0
1,5
1,0
0,5
0
0 10203040
l/min
bar
0,25
0,2
0,15
0,1
0,05
WFP 3000
WFP 5000
9. Service
GARDENA guarantees this product for 12 months (from date of
purchase).This guarantee covers all serious defects of the unit
that can be proved to be material or manufacturing faults. Under
warranty we will either replace the unit or repair it free of charge
if the following conditions apply:
The unit must have been handled properly and in keeping with
the requirements of the operating in-structions.
Neither the purchaser or a non-authorised third party have
attempted to repair the unit.
Parts subject to wear (e.g. rotating unit) are excluded from this
guarantee.
This manufacturer’s guarantee does not affect the user’s existing
warranty claims against the dealer/seller.
If you have any problems with your Fountain Pump, please con-
tact our Service or return the defective unit together with a short
description of the problem – in case of guarantee, with a copy
of the receipt – postage paid to one of the GARDENA Service
Centres listed on the back of this leaflet.
Description of the units: Fountain Pumps
Type: WFP 3000 / WFP 5000
Art. No.: 7909 / 7910
EU directives: Machinery Directive 98/37/EC
Electromagnetic Compatibility 89/336/EC
Low Voltage Directive 73/23/EC
Directive 93/68/EC
Harmonised
European standards: EN 292-1 Ulm, 20.11.2000
EN 292-2
EN 60335-1
EN 60335-2-41
Year of CE marking: 2000 Thomas Heinl
Technical Dept. Manager